The user can manually identify the shifts by diurnal symmetry test - morning vs. afternoon (in kt/h0 space). The second option is to run auto-detection, which automatically suggests the location and value of shifts and drifts in the data. The detected shifts can be manually modified or deleted. The detection runs from a few seconds to a few minutes depending on the volume of data. The automatic recognition identifies these shifts within the recognition uncertainty. Always select the original data if you would like to shift the data manually.


Drawio
bordersimple0
zoom1
inComment0
pageId7602335
custContentId4292797lbox0
diagramDisplayNametime_reference
lbox0
contentVer12
revision23
baseUrlhttps://solargis.atlassian.net/wiki
diagramNametime_reference
pCenter0
width13671928
linksauto
tbstylehidden
height1088


Component

Description

Times series graph

Line graph of original records, records after shifting, and clear-sky. Lines is possible to switch off by clicking on the legend (without pan or zoom tool)

Graph tools

Tools: Reset original view, Back to the previous view, Forward to next view, Pan, Zoom, Edit plot, Edit axis, curve and image parameters, Save the figure. Pan tool is able to use as a zoom tool by right click.

Kt graphs

Graphs show diurnal symmetry (morning vs afternoon) of original and shifted data

Shift overview graph

Line graph showing detected shifts in the dataset with uncertainty. The data are broken into segments, each segment has a uniform shift and its uncertainty.

Dataset

Input dataset for Time reference check

Column

Input column for Time reference check. The detection of time shifts is only based on this column. It must be either GHI or GTI type column.

Time shifts arrow

Shows/hides the list of existing shifts

Existing shifts

List of existing shifts

New shifts

List of new shifts. You can disable time shift by checkbox. After running the auto-detection, the shift is shown with its uncertainty. The color shows the confidence of detected shift: green - high, yellow - medium, red - low.

Auto-detection

Runs the automatic shift recognition.

Import

Opens time shifts importer. You can choose another dataset and import time shifts from them.

New

Creates a new shift. It is possible to create a new shift by selecting the time span in Time series graph (pan and zoom tools must be disabled).

Remove

Deletes shift

Reorder

Reorder time shifts from lowest to highest time stamp.

Time from

Datetime setting the beginning of the span.

Reset min

Resets datetime field to minimum possible value.

Time to

Datetime setting the end of the span.

Reset max

Resets datetime field to maximum possible value.

Time shifts

Sets time shift value

Draw kt diagrams only for the active shift

Allows you to display all records or only records from the actual time shift span.

Redraw graphs

Redraws graphs by actual shifts and settings

Settings

Opens settings window consisting of marker size setting and marker transparency setting for kt plots.

Save

Saves changes

Final save

Saves changes and QC status “TIME_REFERENCE_CHECK” will be assign to the dataset.

Save as

Saves changes into the copy of dataset and QC status “TIME_REFERENCE_CHECK” will be assign to the dataset.

Close

Closes window

...

  • Multi component tests compare related parameters against each other within a test group.

  • Single component test requires a parameter within a test group.

  • We recommend to group related parameters e.g. SPN1 GHI and DNI measurements.

  • Use flag icons to indicate which quality control results to save for particular parameter.

  • Flags of a parameter can be saved only within one test group.

  • Analyst pre-fills test groups by default after import. To change parameter assignment or add / remove test groups use test group editor.

...

image-20240306-100513.pngImage Added

Component

Description

Irradiance columns

Select columns of irradiance data type you want to quality check. Flags will be calculated into respective flag columns. Assign columns into groups - this is required for performing consistency test - testing calculated irradiance components versus measured.

Advanced settings

Opens separated dialog with automatic quality check advanced settings.

run between

Quality check can be performed on a subset of the dataset. If checked, values from both calendar widgets are taken into account.

date from, date to

Defines a subset of the dataset by selecting two dates.

Graph

The graphs including the QC flags are displayed.

Irradiance components

The user can select the irradiances component to be displayed. Plot settings menu is active only for these Graph tabs: Heatmap flag plot, Time series flag plot. 

split heatmap by year

If checked, the heatmap is split by years. This checkbox is active only for the Heatmap flag plot.

view in time zone

The time zone can be selected.

Edit test groups

The user can edit, create or delete a test group.

Run

Will start the process of automatic quality check. The result of the procedure is a flagged instance of every data record (if there are no flag columns, they will be created). Preview dialog (Quality report) is provided to let the user review the results.

Save flags

This button is only enabled after running the quality check. It permanently saves generated flags into the dataset. QC status “AUTOMATIC_QUALITY_CHECK_IRRADIATION” will be assign to the dataset.

...

Test Groups are prefilled by default based on column order. In case default test groups do not correctly assign parameters, it is recommended to reorder columns via metadata editor and set default test groups. It is also possible to manually modify test groups.

...

image-20240306-100116.pngImage Added

Advanced settings

...